All Sectors

Revision: Fire Prevention & Fire Fighting (Basic) — STCW Table A-VI/1-2

🕑 5 min read words Revisionguides

Revision card — STCW Code Table A-VI/1-2, Fire Prevention and Fire Fighting. Mandatory Basic Safety Training module for every seafarer; the core competence is stated plainly in the table itself — minimise the risk of fire and maintain a state of readiness to respond to emergency situations involving fire. Refresher required every 5 years for anyone with designated safety or fire-fighting duties, which in practice means almost everyone.

Fire Chemistry & Classes — Know These Cold

  • The fire triangle — heat, fuel, oxygen. Remove any one side and the fire goes out; every extinguishing method works by attacking one or more sides.
  • Class A — ordinary combustibles (wood, paper, textiles, most cabin/accommodation fires) — water is the primary agent
  • Class B — flammable liquids (fuel oil, paints, solvents) — foam, CO2 or dry powder; never water, which spreads a liquid fire
  • Class C — flammable gases — isolate the supply first if at all possible, then dry powder/CO2
  • Class D — combustible metals (rare shipboard, but examined) — specialist dry powder agents only
  • Electrical fires — treated as their own hazard class in IMO/UK guidance — isolate power first, then CO2 or dry powder; never water on a live electrical fire

Shipboard Fire-Fighting Organisation

  • Know your muster list role cold — fire party, boundary cooling team, or emergency squad — before you ever need it under pressure
  • Know the location of firefighting appliances (extinguishers, hydrants, hose reels, fixed system controls) and emergency escape routes on your own vessel without needing to think about it
  • Fire and smoke detection — automatic alarm systems, and what your first actions are on hearing the fire alarm versus the general emergency alarm

Appliances & Systems

  • Portable extinguishers — matching the correct type to the class of fire is the single most commonly tested practical skill
  • Self-Contained Breathing Apparatus (SCBA) — correct donning, air management, buddy system for any fire party entering smoke-logged spaces
  • Fixed systems — CO2 flooding (with mandatory space evacuation and headcount before release), foam systems, sprinklers, water mist — know which system protects which space on a typical vessel
  • Boundary cooling — cooling the structure around a fire (especially adjacent to fuel tanks or cargo) to prevent spread, even while the fire itself is being fought directly

Quick Self-Check

  • Why is water the wrong first response to a Class B fire, and what should you use instead?
  • What has to happen before a fixed CO2 system is released into a space?
  • Can you name your own muster list fire role without checking the list?

Related Reading

Could You Have Prevented It?

Test your judgement in Crew Connect's Decision Simulator — real incident patterns, real consequences, free to try.

Try the Decision Simulator Free →

Ready to advance your maritime career?

Free verified profile. Certificate tracking. Get found directly by shipping companies — no crewing agent, no placement fees.

Create Free Profile — 60 Seconds

Browse maritime jobs by rank & sector

Chief Officer Jobs DP Operator Jobs Chief Engineer Jobs Offshore Crew Jobs Superyacht Crew Jobs Wind Farm CTV Jobs Jobs for Filipino Seafarers Jobs for UK Seafarers Jobs for Indian Seafarers Jobs for Ukrainian Seafarers Jobs for Russian Seafarers Jobs for Indonesian Seafarers