Maritime Questions › Vetting — Fire & LSA
Tokyo MoU code 08 ("Alarms") and code 07 ("Fire safety") are recorded as separate top-level deficiency categories. Why does a malfunctioning fire detection panel (as opposed to, say, a missing fire extinguisher) tend to be treated as a particularly serious finding?
A. A fire detection panel is the system that converts an undetected incipient fire into a known, actionable emergency at the earliest possible stage — if it fails silently (false "all clear," or a fault that goes unnoticed), every other fire safety control downstream (muster, firefighting response, evacuation) is delayed proportionally, regardless of how well-maintained those downstream controls are
B. Detection panel faults are minor administrative issues with no operational safety implication
C. A detection panel fault is only serious if it occurs in the engine room, never in accommodation
D. Alarms and fire safety are graded identically and the distinction is purely organisational, not risk-based
Sign in or create a free account to see the answer and explanation.
A. PSC inspectors are specifically instructed to find fire/LSA deficiencies even when none exist, to meet inspection quotas
B. These systems are only used in genuine emergencies, so degradation (corroded extinguishers, expired hydrostatic releases, faulty fire detection panels) goes unnoticed in routine operation until an inspector specifically tests them — unlike, say, a leaking pipe, which crew would notice and fix immediately because it affects daily work
C. Fire and LSA equipment is inherently less reliable than other shipboard systems regardless of maintenance
D. These categories were only added to the deficiency code list in 2025 and so naturally show high numbers
Sign in or create a free account to see the answer and explanation.
A. An automatic detention, since CO2 systems are always detainable if misunderstood
B. An automatic full pass, since the physical equipment was correctly identified
C. This scenario is not assessable under SIRE 2.0 because CO2 systems are tested separately from the main inspection
D. A "Hardware" pass but a "Human Factors" failure — the equipment exists and is correctly located, but the crew member cannot demonstrate the procedural knowledge needed to use it safely, which is graded independently and can still result in a "Not as Expected" or "Largely Complies" finding
Sign in or create a free account to see the answer and explanation.
+5 more Vetting — Fire & LSA questions available
Create a free account to practise all 8 questions, track your accuracy, and build your Reputation Score.
Create Free Account