SIRE 2.0's guidance requires that if equipment must be introduced into a tank after an inert gas system failure and emergency precautions, this should happen "after at least 30 minutes after the injection of IG has stopped" with metal components "securely electrically earthed... for at least five hours after the injection of IG has stopped." Why are these two precautions on two different timescales (30 minutes vs. five hours) rather than a single combined waiting period?
A. Both timescales address the identical hazard and either one alone would be sufficient without the other
B. The 30-minute and five-hour figures are interchangeable and either can be applied to either precaution without changing the safety outcome
C. These timescales apply only during daylight hours and are unnecessary if the equipment is introduced at night
D. The two precautions address different hazard mechanisms with different timescales — the 30-minute wait allows immediate post-injection conditions to settle before any equipment enters the tank at all, while the five-hour earthing requirement addresses a longer-persisting static electricity risk from charge that can remain present in the tank atmosphere well after the immediate injection event has ended
Sign in or create a free account to see the answer and explanation.
A. Purging order only affects how long the gas-freeing process takes, with no bearing on tank atmosphere safety
B. This requirement applies only to product tankers, never to crude oil tankers undergoing gas-freeing
C. An inert atmosphere (low oxygen) and a gas-free atmosphere (low hydrocarbon) are both individually safe, but the transition between them passes through a combination of oxygen and hydrocarbon concentrations that can fall within the flammable range — if this intermediate flammable state is reached while any ignition source is present, the tank can explode even though both the starting and ending conditions were safe
D. The flammable condition only exists as a theoretical zone on paper and has no practical ignition risk during normal gas-freeing operations
Sign in or create a free account to see the answer and explanation.
A. Crude oil tanks can develop pyrophoric iron sulphide deposits, which can self-ignite on exposure to air — for a crude tanker, restoring genuine inert gas protection is not optional because the tank itself may contain a latent ignition hazard that product tankers (whose coatings generally inhibit pyrophor formation) typically do not have to the same degree
B. Product tankers are entirely exempt from inert gas requirements under all circumstances, making the comparison moot
C. The stricter standard for crude tankers exists purely as a regulatory formality with no connection to a specific physical hazard difference between crude and product cargoes
D. Pyrophoric deposits are a hazard unique to product tankers, not crude oil tankers
Sign in or create a free account to see the answer and explanation.