Maritime QuestionsFire Emergency

Your examiner asks: "Under the ISM Code Regulation 8, what emergency situations must the SMS address, and what must the contingency plans contain?" Give a complete OOW answer.

A. ISM Code Regulation 8 requires the SMS to include procedures to identify, describe, and respond to potential shipboard emergency situations. These must at minimum cover: fire and explosion; flooding and foundering; collision; grounding; pollution incident; man overboard; piracy/security threat; medical emergency; loss of propulsion or steering; cargo emergency. Each contingency plan must contain: immediate actions; muster procedures; roles and responsibilities; communications internal and external; equipment to be deployed; when to call for external assistance. Plans must be tested through drills and exercises. The OOW must know the location of all contingency plans and their key contents.
B. ISM Regulation 8 only requires fire and abandon ship contingency plans. Other emergencies are covered by SOLAS directly without requiring SMS documentation.
C. Contingency plans are produced by the DPA ashore and kept in the company office. The ship's crew access them by calling the DPA during an emergency.
D. The SMS emergency plans are identical for all vessel types. There is no requirement to tailor them to specific voyage or cargo hazards.
Sign in or create a free account to see the answer and explanation.
Your examiner asks: "Describe the fire triangle and the four internationally recognised classes of fire relevant to shipboard operations. Which extinguishing media are correct for each?"
A. The fire triangle requires three elements simultaneously: heat (ignition source), fuel (combustible material), and oxygen. Remove any one element and the fire goes out. Classes: Class A — solids (wood, rope, bedding) — water, foam, dry powder; Class B — flammable liquids (fuel oil, paint, solvents) — foam, CO2, dry powder; Class C — flammable gases (LPG, acetylene) — dry powder, shut off supply first; Class D — combustible metals (magnesium, titanium, sodium) — specialist dry powder only; Class F (electrical equipment) — CO2, dry powder — NEVER water. Note: electrical fires are sometimes classed separately rather than as a fire class.
B. The fire triangle requires fuel and oxygen only. Heat is automatically generated by combustion and cannot be removed independently. There are two classes of fire: liquid and solid.
C. Class A fires are fought with CO2 only. Class B fires require water fog. Class C fires use dry powder. This sequence applies to all shipboard fires.
D. Water is the universal firefighting medium for all classes of fire at sea. Foam and CO2 are supplementary agents used only when water is unavailable.
Sign in or create a free account to see the answer and explanation.
Your examiner asks: "What types of fire detectors are fitted on cargo ships under SOLAS Chapter II-2, and what are the conditions under which each type is most effective?"
A. Smoke detectors (ionisation or photoelectric): detect combustion particles — most effective for smouldering fires producing visible or invisible smoke before open flame. Heat detectors: either fixed-temperature (alarm at a set temperature, e.g. 57-96 degrees) or rate-of-rise (alarm when temperature rises faster than normal, e.g. 5 degrees per minute) — effective for fast-burning fires. Flame detectors: detect infrared or ultraviolet radiation from open flames — effective in machinery spaces with high background heat. Gas/carbon monoxide detectors: detect CO as an early indicator of smouldering fires. SOLAS II-2/7 requires automatic fire detection and alarm systems in crew accommodation, service spaces, control stations, and cargo spaces as appropriate.
B. SOLAS requires only heat detectors on cargo ships. Smoke detectors are for passenger vessels only. All detectors must be tested annually.
C. A single type of detector (smoke) is approved by SOLAS for use in all spaces on all ship types. Variation between spaces is not permitted.
D. Fire detection on cargo ships is provided exclusively by the ship's fire patrol — electronic detection systems are optional additional equipment.
Sign in or create a free account to see the answer and explanation.
+7 more Fire Emergency questions available

Create a free account to practise all 10 questions, track your accuracy, and build your Reputation Score.

Create Free Account