During the fire event, the fixed gas detection system on deck shows naphtha vapour rising in cargo tank 3 ullage space to 22% LEL. This is likely due to the loss of inert gas pressure — the IG blower runs off the main engine. The cargo system operator is asking what to do. What is the priority action?

A. Immediately check that all cargo tank valves, manifold valves, and ullage plugs are closed and secured. Initiate manual monitoring at the tank tops. Stop all non-essential electrical loads that are non-intrinsically safe near the cargo area. Notify all crew not to use mobile phones, radios, or produce ignition sources on deck. The LEL reading means a flammable atmosphere is developing — ignition sources must be eliminated immediately
B. Open the cargo tank hatches to ventilate the vapour — this will reduce the LEL concentration
C. Continue monitoring and act if the LEL reaches 50%
D. Re-pressurise the cargo tanks using compressed air from the emergency compressor
Sign in or create a free account to see the answer and explanation.
MV SOLWAY STAR, 1435. The engine room fixed fire detection alarm activates on the bridge panel — zone indicated is bilge area, below the main engine. The ER is manned — the chief engineer and two ratings are on watch below. What is the OOW's FIRST action?
A. Sound the general alarm immediately. Inform the Master. Do NOT ring the engine room to ask them to investigate — they are in the fire zone. The general alarm brings the emergency team to their stations and ensures the CO₂ room and fire parties are ready before any further assessment
B. Ring the engine room first to check if it is a real fire or a sensor fault — this avoids a false alarm muster
C. Go to the CO₂ room and stand by to discharge — you may need to act quickly
D. Alert the chief officer and wait for his assessment before sounding general alarm
Sign in or create a free account to see the answer and explanation.
Thirty seconds after the general alarm, the chief engineer radios the bridge: "I can see smoke near the bilge pump. I'm going to check if it's a small oil fire — I'll call you back in two minutes." The fire party is mustering on deck. What is the Master's response?
A. Order the chief engineer and ALL engine room personnel to evacuate immediately and close the ER fire dampers and watertight doors. Do not allow investigation without full BA team and hose in place. Smoke in an ER bilge area of a naphtha carrier is a serious fire risk — vapour ignition can occur in seconds
B. Allow the chief engineer to investigate — he knows the space and if it is small it is better to tackle it immediately
C. Tell the chief engineer to use the local CO₂ extinguisher first and report back
D. Wait the two minutes before taking any further action
Sign in or create a free account to see the answer and explanation.