Maritime Questions › Er Fire Co2 Pollution
The re-entry team opens the ER at 35 minutes. Within 4 minutes a fire detector inside re-activates — re-ignition has occurred around the bilge pump fuel supply. The team evacuates safely. The CO₂ system has now been partially discharged. There is a secondary cylinder bank available for a second release. What is the correct action?
A. Re-seal the engine room immediately. Conduct the full headcount again. Discharge the secondary CO₂ bank. Extend the hold time to a minimum of 60 minutes before any further re-entry attempt. Identify and stop the fuel supply to the fire source through remote-operated valves if possible before the next re-entry
B. Do not discharge the secondary CO₂ — it may not be enough to suppress the fire and you will have no reserve
C. Open the ER ventilation to clear the CO₂ and attack the re-ignition with water mist from the fixed system
D. Attempt boundary cooling with hoses from the ER lobby without sealing the space
Sign in or create a free account to see the answer and explanation.
A. Sound the general alarm immediately. Inform the Master. Do NOT ring the engine room to ask them to investigate — they are in the fire zone. The general alarm brings the emergency team to their stations and ensures the CO₂ room and fire parties are ready before any further assessment
B. Ring the engine room first to check if it is a real fire or a sensor fault — this avoids a false alarm muster
C. Go to the CO₂ room and stand by to discharge — you may need to act quickly
D. Alert the chief officer and wait for his assessment before sounding general alarm
Sign in or create a free account to see the answer and explanation.
A. Order the chief engineer and ALL engine room personnel to evacuate immediately and close the ER fire dampers and watertight doors. Do not allow investigation without full BA team and hose in place. Smoke in an ER bilge area of a naphtha carrier is a serious fire risk — vapour ignition can occur in seconds
B. Allow the chief engineer to investigate — he knows the space and if it is small it is better to tackle it immediately
C. Tell the chief engineer to use the local CO₂ extinguisher first and report back
D. Wait the two minutes before taking any further action
Sign in or create a free account to see the answer and explanation.
+16 more Er Fire Co2 Pollution questions available
Create a free account to practise all 19 questions, track your accuracy, and build your Reputation Score.
Create Free Account