Maritime QuestionsEnclosed Space Whatif

Atmosphere test before entry into a cargo hold that previously carried fishmeal: O₂ 20.6%, H₂S 0 ppm, LEL 0%, CO 8 ppm. The STEL for CO is 100 ppm over 15 minutes. The bosun says "CO is well below the STEL — we can go in." What is the minimum additional requirement before entry proceeds?

A. A CO reading of 8 ppm in a space that has been closed indicates an active CO source — likely biological decay in cargo residues. Entry should not proceed until the source of CO is identified, the space has been ventilated to 0 ppm, and the atmosphere is confirmed stable over two consecutive tests 30 minutes apart
B. Entry can proceed — 8 ppm is well within safe limits
C. Proceed with entry but limit time inside to 15 minutes to stay within the STEL
D. Proceed if the CO level does not increase in the next 5 minutes
Sign in or create a free account to see the answer and explanation.
The bosun approaches you — the duty officer — and says he needs to "pop into the pump room for two minutes" to check the bilge level. The gas meter is on charge. No permit has been raised. He says he knows the space well and has done this dozens of times. What is your response?
A. Allow it — two minutes is too short for hypoxia to develop in a space he knows well
B. Allow it provided he leaves the door open and someone waits at the top of the ladder
C. Stop him. No entry is permitted without a valid atmosphere test and an authorised Enclosed Space Entry permit, regardless of familiarity with the space or duration of entry
D. Allow it — the pump room is not classed as a confined space if it has two means of access
Sign in or create a free account to see the answer and explanation.
Pre-entry atmosphere test at the manhole opening of a cargo hold: O₂ 20.5%, LEL 0%, H₂S 0 ppm, CO 0 ppm. The bosun says "It's fine — readings are all in range, let's go in." The hold contained a grain cargo and has been empty for 18 days. What additional step is essential before entry proceeds?
A. Retest in 30 minutes to confirm stability, then enter without testing lower levels
B. No further steps are needed — all readings are within acceptable parameters
C. Proceed on the basis that 18 days of natural ventilation will have normalised the atmosphere throughout
D. The atmosphere must also be tested at lower levels within the space — at working depth and at the bottom. A safe reading at the entry point does not guarantee safe conditions deeper in the hold
Sign in or create a free account to see the answer and explanation.