Maritime QuestionsEnclosed Space Whatif

Last week's entry into the forward void space was completed without incident. The same job is needed again next week. The bosun suggests that since the space was safe last week and no cargo or ballast operations have occurred since, the pre-entry atmosphere test can be skipped "to save time." What is the correct response?

A. Agree — if no operations affecting the space have occurred, the atmosphere will be unchanged
B. Accept a reduced test — O₂ only at the hatch, since the full test was done last week
C. Allow entry on the basis that the space has natural ventilation through the vent pipes
D. Reject this. A previous safe entry gives no guarantee of current conditions. Atmospheres in enclosed spaces can change without any external operations — through corrosion, biological activity, temperature changes, or adjacent pipe leaks. A full pre-entry atmosphere test is mandatory every time
Sign in or create a free account to see the answer and explanation.
The bosun approaches you — the duty officer — and says he needs to "pop into the pump room for two minutes" to check the bilge level. The gas meter is on charge. No permit has been raised. He says he knows the space well and has done this dozens of times. What is your response?
A. Allow it — two minutes is too short for hypoxia to develop in a space he knows well
B. Allow it provided he leaves the door open and someone waits at the top of the ladder
C. Stop him. No entry is permitted without a valid atmosphere test and an authorised Enclosed Space Entry permit, regardless of familiarity with the space or duration of entry
D. Allow it — the pump room is not classed as a confined space if it has two means of access
Sign in or create a free account to see the answer and explanation.
Pre-entry atmosphere test at the manhole opening of a cargo hold: O₂ 20.5%, LEL 0%, H₂S 0 ppm, CO 0 ppm. The bosun says "It's fine — readings are all in range, let's go in." The hold contained a grain cargo and has been empty for 18 days. What additional step is essential before entry proceeds?
A. Retest in 30 minutes to confirm stability, then enter without testing lower levels
B. No further steps are needed — all readings are within acceptable parameters
C. Proceed on the basis that 18 days of natural ventilation will have normalised the atmosphere throughout
D. The atmosphere must also be tested at lower levels within the space — at working depth and at the bottom. A safe reading at the entry point does not guarantee safe conditions deeper in the hold
Sign in or create a free account to see the answer and explanation.
+9 more Enclosed Space Whatif questions available

Create a free account to practise all 12 questions, track your accuracy, and build your Reputation Score.