Maritime QuestionsEnclosed Space Whatif

Three crew members have been working in a double-bottom void space under a permit valid from 0800–1200. It is now 1215. The job is 90% complete and the team inside estimate 20 more minutes will finish it. The permit has expired. What is the correct action?

A. Evacuate the space immediately. Work must stop while a new atmosphere test is conducted, the permit is re-issued by the officer responsible, and the authorising officer reviews current conditions before re-entry is approved
B. Ask the most senior crew member inside to "self-authorise" a 30-minute extension
C. Allow them to finish — the atmosphere was safe at 1200 and 20 more minutes won't change that
D. Extend the permit verbally and document it later once the job is complete
Sign in or create a free account to see the answer and explanation.
The bosun approaches you — the duty officer — and says he needs to "pop into the pump room for two minutes" to check the bilge level. The gas meter is on charge. No permit has been raised. He says he knows the space well and has done this dozens of times. What is your response?
A. Allow it — two minutes is too short for hypoxia to develop in a space he knows well
B. Allow it provided he leaves the door open and someone waits at the top of the ladder
C. Stop him. No entry is permitted without a valid atmosphere test and an authorised Enclosed Space Entry permit, regardless of familiarity with the space or duration of entry
D. Allow it — the pump room is not classed as a confined space if it has two means of access
Sign in or create a free account to see the answer and explanation.
Pre-entry atmosphere test at the manhole opening of a cargo hold: O₂ 20.5%, LEL 0%, H₂S 0 ppm, CO 0 ppm. The bosun says "It's fine — readings are all in range, let's go in." The hold contained a grain cargo and has been empty for 18 days. What additional step is essential before entry proceeds?
A. Retest in 30 minutes to confirm stability, then enter without testing lower levels
B. No further steps are needed — all readings are within acceptable parameters
C. Proceed on the basis that 18 days of natural ventilation will have normalised the atmosphere throughout
D. The atmosphere must also be tested at lower levels within the space — at working depth and at the bottom. A safe reading at the entry point does not guarantee safe conditions deeper in the hold
Sign in or create a free account to see the answer and explanation.