Maritime QuestionsEnclosed Space Whatif

You are the officer responsible for issuing an ESE permit. The space requires a certified gas tester. The only competent gas tester on board is currently off-watch after a night watch. The Master says: "We sail in two hours — get the job done, it'll only take 30 minutes." What do you do?

A. Issue a provisional permit and test the atmosphere yourself using a visual check and a burning candle
B. Do not issue the permit. The job cannot proceed without a competent person to test the atmosphere. Explain this to the Master clearly. If the Master orders you to proceed regardless, document your objection — this is a SOLAS stop-work situation
C. Wake the gas tester but reduce the required testing to the access hatch only to save time
D. Issue the permit — the CO reading from the last entry two days ago showed the space is safe
Sign in or create a free account to see the answer and explanation.
The bosun approaches you — the duty officer — and says he needs to "pop into the pump room for two minutes" to check the bilge level. The gas meter is on charge. No permit has been raised. He says he knows the space well and has done this dozens of times. What is your response?
A. Allow it — two minutes is too short for hypoxia to develop in a space he knows well
B. Allow it provided he leaves the door open and someone waits at the top of the ladder
C. Stop him. No entry is permitted without a valid atmosphere test and an authorised Enclosed Space Entry permit, regardless of familiarity with the space or duration of entry
D. Allow it — the pump room is not classed as a confined space if it has two means of access
Sign in or create a free account to see the answer and explanation.
Pre-entry atmosphere test at the manhole opening of a cargo hold: O₂ 20.5%, LEL 0%, H₂S 0 ppm, CO 0 ppm. The bosun says "It's fine — readings are all in range, let's go in." The hold contained a grain cargo and has been empty for 18 days. What additional step is essential before entry proceeds?
A. Retest in 30 minutes to confirm stability, then enter without testing lower levels
B. No further steps are needed — all readings are within acceptable parameters
C. Proceed on the basis that 18 days of natural ventilation will have normalised the atmosphere throughout
D. The atmosphere must also be tested at lower levels within the space — at working depth and at the bottom. A safe reading at the entry point does not guarantee safe conditions deeper in the hold
Sign in or create a free account to see the answer and explanation.
+9 more Enclosed Space Whatif questions available

Create a free account to practise all 12 questions, track your accuracy, and build your Reputation Score.

Create Free Account