Maritime Questions › DP — Power Management System
What is the function of the bus tie breaker, and how does its state define open bus versus closed bus operation?
A. The bus tie breaker only controls shore power connections in port
B. It has no relevance to DP redundancy, only to cargo systems
C. The bus tie breaker electrically connects (closes) or separates (opens) sections of the switchboard; in closed bus configuration it is shut, allowing power flow between sections, whereas in open bus configuration it is open, isolating sections so a fault on one cannot propagate to the other
D. Closed bus means the breaker is open; open bus means it is closed — the naming is the reverse of switchboard state
Sign in or create a free account to see the answer and explanation.
A. It is a manual logbook system maintained by the engineering officer
B. It exists solely to control hotel load (accommodation power), separate from DP thrust power
C. It automatically manages generator start/stop, load sharing, bus configuration, and load shedding to ensure sufficient power is always available for DP thrust demand, while protecting against blackout from overload
D. It only logs fuel consumption for reporting purposes
Sign in or create a free account to see the answer and explanation.
A. It refers to manually unloading cargo to reduce vessel draft
B. It is a planned maintenance activity to rotate generator running hours
C. It means switching all power to the emergency generator during normal operations
D. It is an automatic PMS function that disconnects pre-defined non-essential loads (or de-rates thruster demand) when generation capacity is at risk of being exceeded, preventing a generator overload trip that could cascade into a full blackout
Sign in or create a free account to see the answer and explanation.
+6 more DP — Power Management System questions available
Create a free account to practise all 9 questions, track your accuracy, and build your Reputation Score.