Maritime Questions › DP — Drive-Off
CONTINUING: OIM contacts the Master and demands the vessel return to 60m immediately, stating: "Your DPO needs to just get back in position — this is costing us £40,000 per hour in downtime." What is the Master's position?
A. The OIM's authority over operations on the installation means the Master must comply
B. The Master must refuse return to 60m until the consequence analysis is complete and shows the vessel can safely operate there with the current degraded thruster configuration — the OIM's £40,000/hour concern is understood but does not create an obligation to operate the vessel outside its demonstrated safe envelope; the Master should explain this clearly and offer a timeline for when the consequence analysis will be complete
C. Return to 60m but log the OIM's request so liability transfers to them
D. Ask the DPO to try holding at 60m for 15 minutes to demonstrate capability, then reassess
Sign in or create a free account to see the answer and explanation.
A. This is a probable drive-off: AZ1 is producing maximum thrust away from the setpoint, opposite to the environmental force direction — instead of fighting the northerly forces, AZ1 is amplifying the southward movement. The DP system should be demanding northward thrust from AZ1; the 98% south demand confirms a runaway thruster, not a DP system corrective response
B. This is a drift-off — the environmental forces must have reversed suddenly, and the DP system is correctly responding with more southward thrust
C. AZ1 showing 98% demand is normal during a position correction — wait 30 seconds before acting
D. This is normal DP hunting behaviour as the system corrects a minor position oscillation
Sign in or create a free account to see the answer and explanation.
A. Manually stop AZ1 at the thruster control panel to remove the erroneous drive force, then assess remaining thruster status — only after AZ1 is stopped should joystick or manual mode be considered; switching to joystick with AZ1 still running south just adds counter-thrust to a fight you may not win fast enough
B. Reduce AZ1 from 98% to 50% using the thruster controller — a sudden stop might damage the motor
C. Switch to joystick mode immediately and apply full northward thrust on all other thrusters to counter AZ1
D. Switch DP computers — the fault is likely in the control system, not the thruster itself
Sign in or create a free account to see the answer and explanation.