Maritime Questions › DP — Drive-Off
CONTINUING: Chief Engineer reports that the AZ1 thruster controller card has failed and a replacement is not available onboard. Repairs will take a minimum of 18 hours. What are the implications for resuming operations at 60m from the platform?
A. The vessel cannot resume operations at 60m with the original ASOG — the new WCF must be calculated without AZ1, new green/amber/red limits derived for the degraded configuration, and the working distance reviewed; the client must be advised that operations may need to be conducted at a greater standoff or suspended until AZ1 is repaired
B. Operations can resume at 60m provided the weather stays below Hs 1.0m
C. Operations can resume at 60m — three thrusters are sufficient for a DP2 vessel in these conditions
D. The client has the authority to waive the ASOG requirement and approve a return to 60m
Sign in or create a free account to see the answer and explanation.
A. This is a probable drive-off: AZ1 is producing maximum thrust away from the setpoint, opposite to the environmental force direction — instead of fighting the northerly forces, AZ1 is amplifying the southward movement. The DP system should be demanding northward thrust from AZ1; the 98% south demand confirms a runaway thruster, not a DP system corrective response
B. This is a drift-off — the environmental forces must have reversed suddenly, and the DP system is correctly responding with more southward thrust
C. AZ1 showing 98% demand is normal during a position correction — wait 30 seconds before acting
D. This is normal DP hunting behaviour as the system corrects a minor position oscillation
Sign in or create a free account to see the answer and explanation.
A. Manually stop AZ1 at the thruster control panel to remove the erroneous drive force, then assess remaining thruster status — only after AZ1 is stopped should joystick or manual mode be considered; switching to joystick with AZ1 still running south just adds counter-thrust to a fight you may not win fast enough
B. Reduce AZ1 from 98% to 50% using the thruster controller — a sudden stop might damage the motor
C. Switch to joystick mode immediately and apply full northward thrust on all other thrusters to counter AZ1
D. Switch DP computers — the fault is likely in the control system, not the thruster itself
Sign in or create a free account to see the answer and explanation.
+7 more DP — Drive-Off questions available
Create a free account to practise all 10 questions, track your accuracy, and build your Reputation Score.