Maritime QuestionsDP — Drillship / MODU

Following an emergency LMRP disconnect, the OIM and client are pushing to reconnect to the well within 24 hours to minimise well downtime costs. The DPO is not satisfied that the fault that caused the disconnect has been fully identified. What should the DPO's position be?

A. The DPO should not support reconnection until the root cause of the event requiring the disconnect is identified and confirmed corrected or risk-assessed; returning to the well with an unresolved DP fault carries the risk of an immediate second disconnect, potentially without the vessel in an adequate position to protect the well
B. Reconnection after 24 hours is always safe regardless of what caused the disconnect
C. Commercial pressure from the client overrides the DPO's concerns — reconnect and monitor
D. The DPO should log their concerns and reconnect if the Master and OIM agree
Sign in or create a free account to see the answer and explanation.
What is an LMRP disconnect and when is it triggered during a drillship DP operation?
A. An LMRP disconnect occurs automatically whenever the DP system goes to joystick mode
B. The LMRP is only disconnected when drilling operations are completed for the well
C. An LMRP (Lower Marine Riser Package) disconnect is an emergency separation of the riser/BOP stack at the connector below the BOP, triggered when the vessel cannot hold position adequately to prevent riser overstress or when a drive-off/drift-off puts the riser beyond its angular tolerance — it disconnects the vessel from the wellhead before the riser is damaged or pulls the BOP off the wellhead
D. An LMRP disconnect is a planned daily procedure carried out to inspect the BOP
Sign in or create a free account to see the answer and explanation.
What do the riser angle limit colour zones (green, yellow, red) represent on a drillship DP operation?
A. The colour zones represent thruster availability: green = all thrusters online, yellow = one thruster offline, red = two or more offline
B. Green = normal operating range (riser within safe angular limits); Yellow = advisory — riser angle approaching limits, increased monitoring required; Red = riser angle at or beyond limits — LMRP disconnect must be initiated; these limits are defined in the WSOG for the specific well and riser configuration
C. Red means the riser is fully vertical; green means it is at its maximum angle
D. The colours indicate weather severity, not riser angle
Sign in or create a free account to see the answer and explanation.
+7 more DP — Drillship / MODU questions available

Create a free account to practise all 10 questions, track your accuracy, and build your Reputation Score.

Create Free Account