Maritime Questions › DP — Control System Failure (Cascade)

The Master asks the DPO whether the operation should continue now that DP Computer 2 has taken over and appears stable, with the UPS alarm still active. What should the DPO's answer be based on?

A. A simple "yes, continue" since DP Computer 2 is currently functioning
B. Deferring entirely to the client's preference without giving a technical recommendation
C. A clear statement that an uncommanded thrust transient occurred, the root cause of the software fault is not yet understood, and a UPS supporting the control system is degraded — taken together, these mean the redundancy the FMEA assumes may not currently be intact, and a precautionary suspension or reduction in operational tempo should be recommended until these are understood, not just "it looks fine now"
D. A simple "no, never operate again on this vessel" without further investigation
Sign in or create a free account to see the answer and explanation.
On a dual-redundant DP control system, DP Computer 1 (the currently active controller) throws an internal software fault and freezes. What should happen automatically, and what must the DPO verify?
A. The vessel should immediately drop anchor regardless of changeover success
B. No automatic action occurs for a software fault; only hardware faults trigger changeover
C. The system should automatically switch over to DP Computer 2 (the standby/redundant controller) seamlessly, with thrusters continuing under DP2's control without interruption; the DPO must verify the changeover actually occurred cleanly, that DP2 has correct position and reference data, and that no thruster commands were lost or duplicated during the transition
D. Thrusters automatically default to maximum power output until manually reset
Sign in or create a free account to see the answer and explanation.
Generators are running normally and all position reference systems show valid, agreeing positions, yet the vessel still experienced a brief uncommanded thrust transient during the changeover. What category of failure does this indicate, and why does it matter that the DPO correctly identifies it as such?
A. It must be a power generation fault since any thrust transient implies an electrical issue
B. It must be a sensor fault since thrust is downstream of position data
C. The category does not matter — all DP failures are addressed identically regardless of cause
D. This is a control-system/software failure category, distinct from power generation or sensor failures — correctly identifying the category matters because the troubleshooting, the people who need to be involved (DP system OEM/software support, not just the electrical engineer), and the appropriate caution around trusting the "recovered" system are all different from a power or sensor event
Sign in or create a free account to see the answer and explanation.