Maritime Questions › DP — Control System Failure (Cascade)
Modern DP systems often use redundant data networks linking sensors, computers, and thrusters. Following the computer fault, what should the DPO confirm about the network architecture before fully trusting the system?
A. Network architecture is not something the DPO needs to understand; it is purely an IT department concern
B. Redundant networks are always fully independent by design, so no verification is ever needed
C. Only the computers themselves matter; network paths have no bearing on DP redundancy
D. Whether the redundant network path is genuinely independent (separate cabling, switches, and routing) from the path that experienced the fault, or whether they share a common point that could mean a single network fault takes down both — this is the network-layer equivalent of checking physical separation in the FMEA
Sign in or create a free account to see the answer and explanation.
A. The vessel should immediately drop anchor regardless of changeover success
B. The system should automatically switch over to DP Computer 2 (the standby/redundant controller) seamlessly, with thrusters continuing under DP2's control without interruption; the DPO must verify the changeover actually occurred cleanly, that DP2 has correct position and reference data, and that no thruster commands were lost or duplicated during the transition
C. No automatic action occurs for a software fault; only hardware faults trigger changeover
D. Thrusters automatically default to maximum power output until manually reset
Sign in or create a free account to see the answer and explanation.
A. This is a control-system/software failure category, distinct from power generation or sensor failures — correctly identifying the category matters because the troubleshooting, the people who need to be involved (DP system OEM/software support, not just the electrical engineer), and the appropriate caution around trusting the "recovered" system are all different from a power or sensor event
B. It must be a sensor fault since thrust is downstream of position data
C. The category does not matter — all DP failures are addressed identically regardless of cause
D. It must be a power generation fault since any thrust transient implies an electrical issue
Sign in or create a free account to see the answer and explanation.
+7 more DP — Control System Failure (Cascade) questions available
Create a free account to practise all 10 questions, track your accuracy, and build your Reputation Score.
Create Free Account