Olivia: A Routine Cleaning Job, a Hot Furnace and a Phone Call at Midnight
Vessel: OLIVIA — 179.9 m bulk carrier, 20,928 GT, built 2013, Malta flag, composite boiler (exhaust-gas economiser plus oil-fired boiler)
Date / Location: 24 May 2025, about 0255, alongside at South Port, Bluff, New Zealand
Outcome: three crew injured — the night-shift third engineer and a motorman with serious burns, a fitter with bruising; no damage to the ship
Source: TAIC final report MO-2025-204, published 30 October 2026
What Happened
OLIVIA reached Bluff on 23 April 2025 after a difficult passage that included a generator failure and main-engine scavenge-space fires. The planned five-day stay (discharge, then load logs) turned into more than a month. All three generators had crankshaft wear beyond tolerance and needed extensive rebuilding, with spares largely stocked overseas. Maritime New Zealand imposed conditions on 5 May: the ship could not sail until the main and auxiliary engines had been repaired and the root cause found.
With the generators out of service, the oil-fired side of the composite boiler was the only way to make steam. That steam heated fuel and supplied hot water and accommodation heating. Normally the oil-fired side is used for a few days at a time in port, and the boiler is cleaned with compressed air a few days before arrival, once it has been shut down and cooled for days.
The Night
- 23 May, about 2229: the burner flames out. Low steam pressure is noticed; restart attempts fail.
- 2346: a second restart attempt causes a blowback: soot and hot air come out of the air intake and trigger the fire alarm. Nobody is hurt. The master and chief engineer are told there is no urgent issue.
- 24 May, about 0010: the night-shift third engineer asks the day-shift third engineer for help. The second engineer and both third engineers swing out the burner, clean the nozzle and diffuser plate and try again. It fails again.
- The phone call: the night-shift third engineer phones the chief engineer, who is asleep, to ask permission to clean. The third engineer recalled being given permission to clean soot. The chief engineer recalled authorising only the burner nozzle. The second engineer heard only one side of the call.
- About 0200: the fitter opens the access hatch and the motorman blows compressed air onto the boiler tubes with a lance for about 20 minutes. Then, at the burner platform, with the furnace full of white smoke and glowing material visible at the base, the motorman blows air upward into the furnace for 20 to 25 minutes.
- About 0255: as the motorman withdraws the lance, the boiler blows back. All three are thrown backwards. The third engineer and motorman have serious burns to face and arms. The crew cool the burns with cold showers; the fire service and two ambulances arrive about 0335. There was no fire.
Why It Happened (TAIC findings)
- Why the flame went out (likely): a burner air-intake flap with a loose retaining screw, a faulty ignition transformer and soot build-up.
- The trigger (likely): the motorman probably disturbed heated soot while withdrawing the lance, igniting residual fuel left by the failed restarts.
- All three elements were present: air (from the lance and a positive-pressure engine room), fuel residue and heat. The furnace bricks retained heat and no objective check of cooling was made.
- Injury severity (very likely): proper face protection would probably have reduced the injuries. The job hazard analysis listed eye protection, not face protection, and the crew wore none.
- Fatigue (very likely): the senior engineers who made the decisions had been working on the generator repairs and were tired. Hours of rest records showed 12-hour shifts, but actual hours were longer.
- Communication (very likely): the call to the chief engineer left each person with a different picture of what had been approved and what controls applied.
- The safety management system was not used when it was needed. The flame-out was unplanned work under the operator's own manual, which called for a review, a toolbox meeting, an unplanned-work template and a job hazard analysis. None was done. Some officers believed toolbox meetings were only needed for planned work. The boiler JHA that existed was generic: no objective cooling criteria, no vessel-specific method, no trigger to escalate after failed ignitions or a prior blowback. Only the motorman had cleaned this boiler on board, and only at sea after days of cooling.
- Nobody senior was on watch at night. The night shift was a third engineer, a fitter and a motorman. Nobody was there with the authority to oversee higher-risk work.