DP Errors: Position References That Failed Together
Part of the Dynamic Positioning Incidents & Lessons series.
Error type: A hidden common failure: several position references lost at once because they were not independent
Cases compared: DP shuttle tanker gyro heading loss (SF 09/08), DP Class 2 run-off alongside a platform (SF 14/06), DPE 04/21 DGNSS and gyro configuration
Use it for: DPO orals and induction, FMEA and ASOG review, DP annual trials, technical superintendents
Sources: IMCA Safety Flash 09/08; IMCA Safety Flash 14/06; IMCA DP Event bulletin DPE 04/21 (anonymised industry reports)
Redundancy on Paper, Common Failure in the Wiring
A DP vessel is judged on its ability to lose one thing and carry on. These three IMCA reports each describe a vessel that had several position references selected into DP, and lost them together. In none of them did the operators do anything obviously wrong. The failure was in how the references were connected, configured or documented.
The Cases
DP Class 2 shuttle tanker, loss of all references during offtake (IMCA SF 09/08)
A DP Class 2 shuttle tanker lost its position during a DP offtake operation, through the sudden and simultaneous loss of all position reference systems.
- What the team did: The operators were conducting a normal DP offtake with references online.
- The specific error: IMCA's report says investigation found the loss of reference systems was directly caused by incorrect gyro heading, which corrupted all the offset calculations in the DP model. The root cause was erroneous GPS signals reaching all the gyros over a short period of time.
- The barrier that would have caught it: Stricter criteria for accepting position references into the DP system, which the operator put in place, and gyro software to reject erroneous GPS latitude and speed compensation data, which the manufacturer was about to provide.
DP Class 2 vessel alongside a platform, run-off (IMCA SF 14/06)
A DP Class 2 vessel alongside a platform lost its reference systems and was taken into manual control. She was recovered to a safe location without mishap, with no damage to the platform or vessel.
- What the team did: One position reference started to deteriorate. The DPO on watch selected alternative references to maintain positional integrity, in line with normal accepted procedure.
- The specific error: The vessel's configuration linked the faulty reference to several others, so losing one lost the others, including a vertical reference unit. The DP voting algorithm was based on three vertical reference units, but only two were fitted, so the second was rejected and then all other references were rejected. Sensor offsets to the centre of gravity were omitted, and pitch compensation wiring errors amplified pitch rather than compensating for it. These changes were poorly documented.
- The barrier that would have caught it: Configuration checks that go beyond function: IMCA noted that FMEA trials test function, not configuration, and may miss such errors, especially if carried out in calm water. Keep up-to-date records of configurations, offsets, drawings and changes on board.
Keep Reading — It's Free